RD300
Refrigerant Leakage Detector
Features:
Detects all standard refrigerants using a heated diode sensor
LED light at probe tip (with on/off switch) for working in dimly lit areas
LEDs display user-selectable High/Medium/Low levels with sensitivity of 0.25/0.50/0.99 oz per year
Audible and Visual alert with mute button
Low battery indicator
Field replaceable sensor and LED light tip
Complete with leak test bottle, 9V battery, and protective hard carrying case
Detecable Refrigerants R-22, R-134a, R-404a, R-410a, all CFCs, all HCFCs and HFCs
Sensor Heated Diode
Sensitivity Levels High: 0.25oz/yr (7g/yr)
Medium: 0.5oz/yr (14g/yr)
Low: 0.99oz/yr (28g/yr)
Warm Up Time 90 seconds
Auto Power OFF Automatic shut off after 10 minutes
Low Battery Indication LOW-BATT light switches ON
Power Supply 9V Battery
Battery Life 13 hours of continuous use
Operating Conditions 0 to 50°C (32 to 122°F) <80%RH
Storage Conditions -10 to 60°C (14 to 140°F) <70% RH
Flexible Probe Length 450mm (18")
Dimensions 184 x 70 x 40mm (7.2" x 2.8" x 1.6")
Weight 280g (10.0oz)